This is due to the copying of large files that’s utilized to flash your CIC.Īt this point, you’re software is completely set up for coding and/or flashing. Depending on your chassis, this will appear to freeze at times while copying CI*** files/folders.
You will only need to use button 6 if you’re planning on flashing updated software to any of your modules.īutton 6, Click this button to import the files required to update the software on your modules. At this point, you’re able to begin coding and utilizing INPA for troubleshooting. If not, this import process will not work.īutton 2, Select the NCS Expert folder that you copied to your C: drive in step 15.īutton 3, Select the Ediabas folder that you copied to your C: drive in step 15.īutton 4, Select the EC-APPS\NFS folder that you copied to your C: drive in step 15.īutton 5, Click this button to begin the process of importing your DATEN. The DATEN folder must not be a zipped file and must contain the following folders (cfgdat, data, daten, ecu, format, kmmData, sgdat, work).
NOTE: For 32 bit systems, select “NCSEXPERT” for 64 bit systems, select “NCSEXPER_64”.ġ6.Run the BMW Coding Tool by right clicking and “Run as Administrator”, the select “Yes” when asked to allow this program to make changes to your computer.ġ7.We will define a few settings on this screen so that we can import the DATENs.īutton 1, Browse to the location where you downloaded your SP-DATEN and click the chassis folder (i.e., E89). NOTE: You won’t have the NCSEXPER64 folder yet.ġ5.Select the downloaded folders below and copy them to your C: Drive. Now, we’ll copy a pre-configured set up with English files and translations already in place, plus select which NCS Expert version you need to use (32 or 64 bit).
This install was primarily used to create all the environment variables and registry entries necessary to run these programs. No need to do this, can use software without rebooting.ġ4.Select the 3 folders below and delete them. We can change this later if need be.ġ3.Select “No, I will restart the computer later” and click “Finish”. Select the default location for each of the programs being installed on next few screens.ħ.Select the default Start Menu Folder by clicking “Next”.Ĩ.Uncheck both “Execute backup and restore wizard and click next.ġ0.Select the default interface by clicking “Next”.ġ1.Select default Com Port (Com 1) by clicking next.
5.5.Select “I accept the agreement”, then “Next” and select “Next” when you’re done reading the release notes.Ħ.Accept the default install options (we’ll worry about the KDCAN drivers in a later step). I also found the version of WinKFP contained in Standard Tools v2.10 was a bit rubbery, so updated it to v2. Manually adding the new files ensured that some of the files were not erased or overwritten and the modified version has been successfully tested on both an E38 and E36 so far. I then manually copied the files into the corresponding files of my existing c: INPA folders, choosing to update only files with a more recently modified/created date. I created a folder named EC-APPS on my hard drive, then followed only step 3 of the INPA 2010 installation instructions to install all the relevant files into the new folder. I also found the version of WinKFP contained in Standard Tools v2.10 was a bit rubbery, so updated it to v2.5. 2.405 ifhsrv can not conect with DIS? Last edited by trigital at 03:40 AM. Download Regina La O Margine De Sat Fileshare. I use a passthru interface as REMOTE and can start only after DIS conect to the car. The v6.4.7 ifhsrv32 always call the ediabas v6.4.7. Problem is when I try to use NCS, the new.prg files is not OK for 6.4.7 that is currently use by old folder. Thanks, I did something like that, I rename to EDIABAS2 and use as EDIABAS the old folder.
Hello Trigital, try creating a new folder called 'old', in Ediabas - c: ediabas old - and copy all the sub-folders from Ediabas v6.4.7, then manually start ifhsrv32 in the c: ediabas old bin folder ( Courtesy of xDrive).